# Air cooled Witherspoon fan policy for PDM.
|
|
#
|
|
# An air cooled Witherspoon requires a minimum of three functional fans
|
|
# enclosures or six functional fan rotors across all enclosures.
|
|
# If the number of functional fan enclosures is below three, soft poweroff
|
|
# the system, whereas if the number of fan rotors drop below six, an
|
|
# immediate hard poweroff of the system occurs.
|
|
|
|
- name: fan enclosures
|
|
description: >
|
|
'An air cooled Witherspoon has four fan enclosures to monitor.'
|
|
class: group
|
|
group: path
|
|
members:
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan0
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan1
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan2
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan3
|
|
|
|
- name: fan rotors
|
|
description: >
|
|
'An air cooled Witherspoon has eight fan rotors to monitor.'
|
|
class: group
|
|
group: path
|
|
members:
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan0/fan0_0
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan0/fan0_1
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan1/fan1_0
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan1/fan1_1
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan2/fan2_0
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan2/fan2_1
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan3/fan3_0
|
|
- meta: FAN
|
|
path: /xyz/openbmc_project/inventory/system/chassis/motherboard/fan3/fan3_1
|
|
|
|
- name: chassis state
|
|
description: >
|
|
'Witherspoon has a single chassis to monitor.'
|
|
class: group
|
|
group: path
|
|
members:
|
|
- meta: CHASSISSTATE
|
|
path: /xyz/openbmc_project/state/chassis0
|
|
|
|
- name: chassis
|
|
description: >
|
|
'Witherspoon has a single chassis to monitor.'
|
|
class: group
|
|
group: path
|
|
members:
|
|
- meta: CHASSIS
|
|
path: /xyz/openbmc_project/inventory/system/chassis
|
|
|
|
- name: fan present
|
|
description: >
|
|
'Monitor the presence state of each fan.'
|
|
class: group
|
|
group: property
|
|
type: boolean
|
|
members:
|
|
- interface: xyz.openbmc_project.Inventory.Item
|
|
meta: PRESENT
|
|
property: Present
|
|
|
|
- name: fan functional
|
|
description: >
|
|
'Monitor the functional state of each fan.'
|
|
class: group
|
|
group: property
|
|
type: boolean
|
|
members:
|
|
- interface: xyz.openbmc_project.State.Decorator.OperationalStatus
|
|
meta: FUNCTIONAL
|
|
property: Functional
|
|
|
|
- name: chassis powered
|
|
description: >
|
|
'Monitor the chassis power state.'
|
|
class: group
|
|
group: property
|
|
type: string
|
|
members:
|
|
- interface: xyz.openbmc_project.State.Chassis
|
|
meta: CHASSIS_STATE
|
|
property: CurrentPowerState
|
|
|
|
- name: chassis air cooled
|
|
description: >
|
|
'Monitor the chassis cooling type.'
|
|
class: group
|
|
group: property
|
|
type: boolean
|
|
members:
|
|
- interface: xyz.openbmc_project.Inventory.Decorator.CoolingType
|
|
meta: COOLING_TYPE
|
|
property: WaterCooled
|
|
|
|
- name: watch fan present
|
|
description: >
|
|
'Trigger logic on fan enclosure presence state changes.'
|
|
class: watch
|
|
watch: property
|
|
paths: fan enclosures
|
|
properties: fan present
|
|
callback: check cooling type
|
|
|
|
- name: watch fan functional
|
|
description: >
|
|
'Trigger logic on fan enclosure functional state changes.'
|
|
class: watch
|
|
watch: property
|
|
paths: fan enclosures
|
|
properties: fan functional
|
|
callback: check cooling type
|
|
|
|
- name: watch fan rotor functional
|
|
description: >
|
|
'Trigger logic on fan rotor functional state changes.'
|
|
class: watch
|
|
watch: property
|
|
paths: fan rotors
|
|
properties: fan functional
|
|
callback: check cooling type
|
|
|
|
- name: watch chassis state
|
|
description: >
|
|
'Trigger logic on chassis power state changes.'
|
|
class: watch
|
|
watch: property
|
|
paths: chassis state
|
|
properties: chassis powered
|
|
callback: check cooling type
|
|
|
|
- name: watch cooling type
|
|
description: >
|
|
'Maintain a cache of the chassis cooling type.'
|
|
class: watch
|
|
watch: property
|
|
paths: chassis
|
|
properties: chassis air cooled
|
|
|
|
- name: check cooling type
|
|
description: >
|
|
'If this condition passes the chassis is air cooled.'
|
|
class: condition
|
|
condition: count
|
|
paths: chassis
|
|
properties: chassis air cooled
|
|
callback: check power
|
|
countop: '=='
|
|
countbound: 0
|
|
op: '=='
|
|
bound: true
|
|
|
|
- name: check power
|
|
description: >
|
|
'If the chassis has power, check fans.'
|
|
class: condition
|
|
condition: count
|
|
paths: chassis state
|
|
properties: chassis powered
|
|
callback: check fans
|
|
countop: '>'
|
|
countbound: 0
|
|
op: '=='
|
|
bound: xyz.openbmc_project.State.Chassis.PowerState.On
|
|
|
|
- name: check fans
|
|
description: >
|
|
'Verify there are at least three functional fan enclosures and at least
|
|
six functional fan rotors, power off if not.'
|
|
class: callback
|
|
callback: group
|
|
members:
|
|
- check group presence
|
|
- check group functional enclosures
|
|
- check group functional rotors
|
|
|
|
- name: check group presence
|
|
description: >
|
|
'If this condition passes more than one fan has been unplugged
|
|
for more than 25 seconds. Shut the system down. Count present
|
|
fans rather than non-present fans since the latter would pass
|
|
if the fan has not been created for some reason.
|
|
|
|
For a more detailed definition of unplugged, consult the documentation
|
|
of xyz.openbmc_project.Inventory.Item and/or the documentation
|
|
of the fan inventory object implementation.'
|
|
class: condition
|
|
condition: count
|
|
paths: fan enclosures
|
|
properties: fan present
|
|
defer: 25000000us
|
|
callback: log and shutdown
|
|
countop: '<'
|
|
countbound: 3
|
|
op: '=='
|
|
bound: true
|
|
|
|
- name: check group functional enclosures
|
|
description: >
|
|
'If this condition passes more than one fan enclosure in the group has been
|
|
marked as nonfunctional for five seconds. Shut the system down.
|
|
|
|
For a more detailed definition of nonfunctional, consult the documentation
|
|
of xyz.openbmc_project.State.Decorator.OperationalStatus and/or the
|
|
documentation of the fan inventory object implementation.'
|
|
class: condition
|
|
condition: count
|
|
paths: fan enclosures
|
|
properties: fan functional
|
|
defer: 5000000us
|
|
callback: log and shutdown
|
|
countop: '>'
|
|
countbound: 1
|
|
op: '=='
|
|
bound: false
|
|
|
|
- name: check group functional rotors
|
|
description: >
|
|
'If this condition passes more than two fan rotors in the group have been
|
|
marked as nonfunctional for five seconds. Immediately power off.
|
|
|
|
For a more detailed definition of nonfunctional, consult the documentation
|
|
of xyz.openbmc_project.State.Decorator.OperationalStatus and/or the
|
|
documentation of the fan inventory object implementation.'
|
|
class: condition
|
|
condition: count
|
|
paths: fan rotors
|
|
properties: fan functional
|
|
defer: 5000000us
|
|
callback: log and poweroff
|
|
countop: '>'
|
|
countbound: 2
|
|
op: '=='
|
|
bound: false
|
|
|
|
- name: log and poweroff
|
|
description: >
|
|
'Immediately poweroff, log an event in the journal, and create an
|
|
error log.'
|
|
class: callback
|
|
callback: group
|
|
members:
|
|
- hard poweroff
|
|
- log hard poweroff
|
|
- create shutdown error
|
|
|
|
- name: log and shutdown
|
|
description: >
|
|
'Shut the system down, log an event in the journal, and create an
|
|
error log.'
|
|
class: callback
|
|
callback: group
|
|
members:
|
|
- shutdown
|
|
- log shutdown
|
|
- create shutdown error
|
|
|
|
- name: hard poweroff
|
|
description: >
|
|
'Immediately power off the system.'
|
|
class: callback
|
|
callback: method
|
|
service: org.freedesktop.systemd1
|
|
path: /org/freedesktop/systemd1
|
|
interface: org.freedesktop.systemd1.Manager
|
|
method: StartUnit
|
|
args:
|
|
- value: obmc-chassis-hard-poweroff@0.target
|
|
type: string
|
|
- value: replace
|
|
type: string
|
|
|
|
- name: shutdown
|
|
description: >
|
|
'Shut down the system.'
|
|
class: callback
|
|
callback: method
|
|
service: org.freedesktop.systemd1
|
|
path: /org/freedesktop/systemd1
|
|
interface: org.freedesktop.systemd1.Manager
|
|
method: StartUnit
|
|
args:
|
|
- value: obmc-host-shutdown@0.target
|
|
type: string
|
|
- value: replace
|
|
type: string
|
|
|
|
- name: log hard poweroff
|
|
description: >
|
|
'Log a hard poweroff event to the systemd journal.'
|
|
class: callback
|
|
callback: journal
|
|
paths: chassis state
|
|
properties: chassis powered
|
|
severity: ERR
|
|
message: Immediate poweroff of system. There are not enough functional fans.
|
|
|
|
- name: log shutdown
|
|
description: >
|
|
'Log a shutdown event to the systemd journal.'
|
|
class: callback
|
|
callback: journal
|
|
paths: chassis state
|
|
properties: chassis powered
|
|
severity: ERR
|
|
message: Request shutdown of system. There are not enough functional fans.
|
|
|
|
- name: create shutdown error
|
|
description: >
|
|
'Create a Fan Shutdown Error log.'
|
|
class: callback
|
|
callback: elog
|
|
paths: chassis state
|
|
properties: chassis powered
|
|
error: xyz::openbmc_project::State::Shutdown::Inventory::Error::Fan
|