1: &TEMP_DEFAULTS bExp: 0 entityID: 30 entityInstance: 1 interfaces: xyz.openbmc_project.Sensor.Value: Value: Offsets: 255: type: double multiplierM: 1 mutability: Mutability::Write|Mutability::Read offsetB: 0 path: /xyz/openbmc_project/sensors/temperature/TS1_Temp rExp: 0 readingType: readingData sensorNamePattern: nameLeaf sensorReadingType: 1 sensorType: 1 serviceInterface: org.freedesktop.DBus.Properties unit: xyz.openbmc_project.Sensor.Value.Unit.DegreesC 2: <<: *TEMP_DEFAULTS entityInstance: 2 path: /xyz/openbmc_project/sensors/temperature/TS2_Temp 3: <<: *TEMP_DEFAULTS entityInstance: 3 path: /xyz/openbmc_project/sensors/temperature/TS3_Temp 4: <<: *TEMP_DEFAULTS entityInstance: 4 path: /xyz/openbmc_project/sensors/temperature/TS4_Temp 5: <<: *TEMP_DEFAULTS entityInstance: 5 path: /xyz/openbmc_project/sensors/temperature/TS5_Temp 6: <<: *TEMP_DEFAULTS entityInstance: 6 path: /xyz/openbmc_project/sensors/temperature/TS6_Temp 243: <<: *TEMP_DEFAULTS entityInstance: 58 path: /xyz/openbmc_project/sensors/temperature/PSU0_TEMP 244: <<: *TEMP_DEFAULTS entityInstance: 59 path: /xyz/openbmc_project/sensors/temperature/PSU1_TEMP 37: &FAN_DEFAULTS entityID: 29 entityInstance: 13 sensorType: 4 path: /xyz/openbmc_project/sensors/fan_tach/FAN3_1 sensorReadingType: 1 multiplierM: 100 offsetB: 0 rExp: 0 unit: xyz.openbmc_project.Sensor.Value.Unit.RPMS mutability: Mutability::Write|Mutability::Read serviceInterface: org.freedesktop.DBus.Properties readingType: readingData sensorNamePattern: nameLeaf interfaces: xyz.openbmc_project.Sensor.Value: Value: Offsets: 0x0: type: double 40: <<: *FAN_DEFAULTS entityInstance: 16 path: /xyz/openbmc_project/sensors/fan_tach/FAN3_2 43: <<: *FAN_DEFAULTS entityInstance: 19 path: /xyz/openbmc_project/sensors/fan_tach/FAN4_1 46: <<: *FAN_DEFAULTS entityInstance: 22 path: /xyz/openbmc_project/sensors/fan_tach/FAN4_2 49: <<: *FAN_DEFAULTS entityInstance: 25 path: /xyz/openbmc_project/sensors/fan_tach/FAN5_1 52: <<: *FAN_DEFAULTS entityInstance: 28 path: /xyz/openbmc_project/sensors/fan_tach/FAN5_2 55: <<: *FAN_DEFAULTS entityInstance: 31 path: /xyz/openbmc_project/sensors/fan_tach/FAN6_1 58: <<: *FAN_DEFAULTS entityInstance: 34 path: /xyz/openbmc_project/sensors/fan_tach/FAN6_2 61: <<: *FAN_DEFAULTS entityInstance: 37 path: /xyz/openbmc_project/sensors/fan_tach/FAN7_1 64: <<: *FAN_DEFAULTS entityInstance: 40 path: /xyz/openbmc_project/sensors/fan_tach/FAN7_2 67: <<: *FAN_DEFAULTS entityInstance: 43 path: /xyz/openbmc_project/sensors/fan_tach/FAN8_1 70: <<: *FAN_DEFAULTS entityInstance: 46 path: /xyz/openbmc_project/sensors/fan_tach/FAN8_2 245: <<: *FAN_DEFAULTS entityInstance: 60 path: /xyz/openbmc_project/sensors/fan_tach/PSU0_fan1 246: <<: *FAN_DEFAULTS entityInstance: 61 path: /xyz/openbmc_project/sensors/fan_tach/PSU1_fan1 73: &VOLTAGE_DEFAULTS entityID: 0x13 entityInstance: 9 sensorType: 0x02 path: /xyz/openbmc_project/sensors/voltage/S0_0V8_VDDC_SOC sensorReadingType: 0x01 multiplierM: 5 offsetB: 0 bExp: 0 unit: xyz.openbmc_project.Sensor.Value.Unit.Volts rExp: -3 serviceInterface: org.freedesktop.DBus.Properties readingType: readingData interfaces: xyz.openbmc_project.Sensor.Value: Value: Offsets: 0xFF: type: double 74: <<: *VOLTAGE_DEFAULTS entityInstance: 11 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S0_0V75_PCP 75: <<: *VOLTAGE_DEFAULTS entityInstance: 13 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S0_1V2_VDDQ0123 76: <<: *VOLTAGE_DEFAULTS entityInstance: 15 multiplierM: 4 path: /xyz/openbmc_project/sensors/voltage/S0_0V6_VTT0123 77: <<: *VOLTAGE_DEFAULTS entityInstance: 17 multiplierM: 15 path: /xyz/openbmc_project/sensors/voltage/S0_2V5_VPP0123 78: <<: *VOLTAGE_DEFAULTS entityInstance: 19 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S0_1V2_VDDQ4567 79: <<: *VOLTAGE_DEFAULTS entityInstance: 21 multiplierM: 4 path: /xyz/openbmc_project/sensors/voltage/S0_0V6_VTT4567 80: <<: *VOLTAGE_DEFAULTS entityInstance: 23 multiplierM: 15 path: /xyz/openbmc_project/sensors/voltage/S0_2V5_VPP4567 81: <<: *VOLTAGE_DEFAULTS entityInstance: 25 multiplierM: 5 path: /xyz/openbmc_project/sensors/voltage/S0_0V85_RCA 82: <<: *VOLTAGE_DEFAULTS entityInstance: 27 multiplierM: 11 path: /xyz/openbmc_project/sensors/voltage/S0_1V8_VDDH 83: <<: *VOLTAGE_DEFAULTS entityInstance: 29 multiplierM: 9 path: /xyz/openbmc_project/sensors/voltage/S0_1V5_VDDH 84: <<: *VOLTAGE_DEFAULTS entityInstance: 31 multiplierM: 11 path: /xyz/openbmc_project/sensors/voltage/S0_1V8_SOC 85: <<: *VOLTAGE_DEFAULTS entityInstance: 33 multiplierM: 11 path: /xyz/openbmc_project/sensors/voltage/S0_1V8_PCP 86: <<: *VOLTAGE_DEFAULTS entityInstance: 35 multiplierM: 20 path: /xyz/openbmc_project/sensors/voltage/S0_3V3_SOC 87: <<: *VOLTAGE_DEFAULTS entityInstance: 10 multiplierM: 5 path: /xyz/openbmc_project/sensors/voltage/S1_0V8_VDDC_SOC 88: <<: *VOLTAGE_DEFAULTS entityInstance: 12 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S1_0V75_PCP 89: <<: *VOLTAGE_DEFAULTS entityInstance: 14 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S1_1V2_VDDQ0123 90: <<: *VOLTAGE_DEFAULTS entityInstance: 16 multiplierM: 4 path: /xyz/openbmc_project/sensors/voltage/S1_0V6_VTT0123 91: <<: *VOLTAGE_DEFAULTS entityInstance: 18 multiplierM: 15 path: /xyz/openbmc_project/sensors/voltage/S1_2V5_VPP0123 92: <<: *VOLTAGE_DEFAULTS entityInstance: 20 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S1_1V2_VDDQ4567 93: <<: *VOLTAGE_DEFAULTS entityInstance: 22 multiplierM: 4 path: /xyz/openbmc_project/sensors/voltage/S1_0V6_VTT4567 94: <<: *VOLTAGE_DEFAULTS entityInstance: 24 multiplierM: 15 path: /xyz/openbmc_project/sensors/voltage/S1_2V5_VPP4567 95: <<: *VOLTAGE_DEFAULTS entityInstance: 26 multiplierM: 5 path: /xyz/openbmc_project/sensors/voltage/S1_0V85_RCA 96: <<: *VOLTAGE_DEFAULTS entityInstance: 28 multiplierM: 11 path: /xyz/openbmc_project/sensors/voltage/S1_1V8_VDDH 97: <<: *VOLTAGE_DEFAULTS entityInstance: 30 multiplierM: 9 path: /xyz/openbmc_project/sensors/voltage/S1_1V5_VDDH 98: <<: *VOLTAGE_DEFAULTS entityInstance: 32 multiplierM: 11 path: /xyz/openbmc_project/sensors/voltage/S1_1V8_SOC 99: <<: *VOLTAGE_DEFAULTS entityInstance: 34 multiplierM: 11 path: /xyz/openbmc_project/sensors/voltage/S1_1V8_PCP 100: <<: *VOLTAGE_DEFAULTS entityInstance: 36 multiplierM: 20 path: /xyz/openbmc_project/sensors/voltage/S1_3V3_SOC 101: <<: *VOLTAGE_DEFAULTS entityInstance: 37 multiplierM: 20 path: /xyz/openbmc_project/sensors/voltage/3V3_SB 102: <<: *VOLTAGE_DEFAULTS entityInstance: 38 multiplierM: 18 path: /xyz/openbmc_project/sensors/voltage/VBAT_RTC 230: <<: *VOLTAGE_DEFAULTS entityInstance: 74 multiplierM: 20 rExp: -1 path: /xyz/openbmc_project/sensors/voltage/PSU0_VINPUT 231: <<: *VOLTAGE_DEFAULTS entityInstance: 75 multiplierM: 20 rExp: -1 path: /xyz/openbmc_project/sensors/voltage/PSU1_VINPUT 232: <<: *VOLTAGE_DEFAULTS entityInstance: 76 multiplierM: 20 rExp: -2 path: /xyz/openbmc_project/sensors/voltage/PSU0_VOUTPUT 233: <<: *VOLTAGE_DEFAULTS entityInstance: 77 multiplierM: 20 rExp: -2 path: /xyz/openbmc_project/sensors/voltage/PSU1_VOUTPUT 105: <<: *TEMP_DEFAULTS entityInstance: 13 path: /xyz/openbmc_project/sensors/temperature/S0_DIMMG1_Temp 106: <<: *TEMP_DEFAULTS entityInstance: 14 path: /xyz/openbmc_project/sensors/temperature/S1_DIMMG1_Temp 107: <<: *TEMP_DEFAULTS entityInstance: 15 path: /xyz/openbmc_project/sensors/temperature/S0_SOC_Temp 108: <<: *TEMP_DEFAULTS entityInstance: 16 path: /xyz/openbmc_project/sensors/temperature/S0_SOC_VRD_Temp 109: <<: *TEMP_DEFAULTS entityInstance: 17 path: /xyz/openbmc_project/sensors/temperature/S0_DIMM_VRD_Temp 110: <<: *TEMP_DEFAULTS entityInstance: 18 path: /xyz/openbmc_project/sensors/temperature/S0_Core_VRD_Temp 111: <<: *TEMP_DEFAULTS entityInstance: 19 path: /xyz/openbmc_project/sensors/temperature/S0_DIMMG0_Temp 112: &power sensorType: 0x08 path: /xyz/openbmc_project/sensors/power/S0_CPU_Pwr entityID: 19 entityInstance: 39 sensorReadingType: 0x01 multiplierM: 200 offsetB: 0 bExp: 0 unit: xyz.openbmc_project.Sensor.Value.Unit.Watts rExp: -2 serviceInterface: org.freedesktop.DBus.Properties readingType: readingData interfaces: xyz.openbmc_project.Sensor.Value: Value: Offsets: 0xFF: type: double 113: <<: *power entityInstance: 40 multiplierM: 39 path: /xyz/openbmc_project/sensors/power/S0_DIMM_VR1_Pwr 114: <<: *power entityInstance: 41 multiplierM: 39 path: /xyz/openbmc_project/sensors/power/S0_DIMM_VR2_Pwr 115: <<: *power entityInstance: 42 multiplierM: 80 path: /xyz/openbmc_project/sensors/power/S0_MEM_Pwr 116: <<: *VOLTAGE_DEFAULTS entityInstance: 43 multiplierM: 10 path: /xyz/openbmc_project/sensors/voltage/S0_CPU_VCORE 117: <<: *VOLTAGE_DEFAULTS entityInstance: 44 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S0_DIMM_VR1_Volt 118: <<: *VOLTAGE_DEFAULTS entityInstance: 45 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S0_DIMM_VR2_Volt 119: <<: *VOLTAGE_DEFAULTS entityInstance: 46 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S0_DIMM_DDR_Volt 123: <<: *TEMP_DEFAULTS entityInstance: 20 path: /xyz/openbmc_project/sensors/temperature/S1_SOC_Temp 124: <<: *TEMP_DEFAULTS entityInstance: 21 path: /xyz/openbmc_project/sensors/temperature/S1_SOC_VRD_Temp 125: <<: *TEMP_DEFAULTS entityInstance: 22 path: /xyz/openbmc_project/sensors/temperature/S1_DIMM_VRD_Temp 126: <<: *TEMP_DEFAULTS entityInstance: 23 path: /xyz/openbmc_project/sensors/temperature/S1_Core_VRD_Temp 127: <<: *TEMP_DEFAULTS entityInstance: 24 path: /xyz/openbmc_project/sensors/temperature/S1_DIMMG0_Temp 128: <<: *power entityInstance: 47 multiplierM: 200 path: /xyz/openbmc_project/sensors/power/S1_CPU_Pwr 129: <<: *power entityInstance: 48 multiplierM: 39 path: /xyz/openbmc_project/sensors/power/S1_DIMM_VR1_Pwr 130: <<: *power entityInstance: 49 multiplierM: 39 path: /xyz/openbmc_project/sensors/power/S1_DIMM_VR2_Pwr 131: <<: *power entityInstance: 50 multiplierM: 80 path: /xyz/openbmc_project/sensors/power/S1_MEM_Pwr 132: <<: *VOLTAGE_DEFAULTS entityInstance: 51 multiplierM: 10 path: /xyz/openbmc_project/sensors/voltage/S1_CPU_VCORE 133: <<: *VOLTAGE_DEFAULTS entityInstance: 52 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S1_DIMM_VR1_Volt 134: <<: *VOLTAGE_DEFAULTS entityInstance: 53 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S1_DIMM_VR2_Volt 135: <<: *VOLTAGE_DEFAULTS entityInstance: 54 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S1_DIMM_DDR_Volt 145: <<: *VOLTAGE_DEFAULTS entityInstance: 58 multiplierM: 5 path: /xyz/openbmc_project/sensors/voltage/S0_SOC_Volt 146: <<: *VOLTAGE_DEFAULTS entityInstance: 59 multiplierM: 5 path: /xyz/openbmc_project/sensors/voltage/S1_SOC_Volt 152: <<: *power entityInstance: 60 multiplierM: 80 path: /xyz/openbmc_project/sensors/power/S0_RCA_VR_Pwr 153: <<: *VOLTAGE_DEFAULTS entityInstance: 55 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S0_RCA_VR_Volt 154: <<: *TEMP_DEFAULTS entityInstance: 25 path: /xyz/openbmc_project/sensors/temperature/S0_RCA_VR_Temp 155: <<: *power entityInstance: 61 multiplierM: 80 path: /xyz/openbmc_project/sensors/power/S1_RCA_VR_Pwr 156: <<: *VOLTAGE_DEFAULTS entityInstance: 56 multiplierM: 7 path: /xyz/openbmc_project/sensors/voltage/S1_RCA_VR_Volt 157: <<: *TEMP_DEFAULTS entityInstance: 26 path: /xyz/openbmc_project/sensors/temperature/S1_RCA_VR_Temp 240: <<: *power entityInstance: 84 multiplierM: 80 rExp: -1 path: /xyz/openbmc_project/sensors/power/PSU0_POUTPUT 241: <<: *power entityInstance: 85 multiplierM: 80 rExp: -1 path: /xyz/openbmc_project/sensors/power/PSU1_POUTPUT 242: <<: *power entityInstance: 57 multiplierM: 80 rExp: -1 path: /xyz/openbmc_project/sensors/power/total_power 238: <<: *power entityInstance: 82 multiplierM: 80 rExp: -1 path: /xyz/openbmc_project/sensors/power/PSU0_PINPUT 239: <<: *power entityInstance: 83 multiplierM: 80 rExp: -1 path: /xyz/openbmc_project/sensors/power/PSU1_PINPUT 169: ¤t sensorType: 0x03 path: /xyz/openbmc_project/sensors/current/S0_Core_VRD_Curr entityID: 19 entityInstance: 64 sensorReadingType: 0x01 multiplierM: 160 offsetB: 0 bExp: 0 unit: xyz.openbmc_project.Sensor.Value.Unit.Amperes rExp: -3 serviceInterface: org.freedesktop.DBus.Properties readingType: readingData interfaces: xyz.openbmc_project.Sensor.Value: Value: Offsets: 0xFF: type: double 170: <<: *current entityInstance: 66 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S0_SOC_VRD_Curr 171: <<: *current entityInstance: 68 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S0_DIMM_VR1_Curr 172: <<: *current entityInstance: 70 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S0_DIMM_VR2_Curr 173: <<: *current entityInstance: 72 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S0_RCA_VRD_Curr 174: <<: *current entityInstance: 65 multiplierM: 160 path: /xyz/openbmc_project/sensors/current/S1_Core_VRD_Curr 175: <<: *current entityInstance: 67 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S1_SOC_VRD_Curr 176: <<: *current entityInstance: 69 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S1_DIMM_VR1_Curr 177: <<: *current entityInstance: 71 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S1_DIMM_VR2_Curr 178: <<: *current entityInstance: 73 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/S1_RCA_VRD_Curr 234: <<: *current entityInstance: 78 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/PSU0_IINPUT 235: <<: *current entityInstance: 79 multiplierM: 80 path: /xyz/openbmc_project/sensors/current/PSU1_IINPUT 236: <<: *current entityInstance: 80 multiplierM: 160 path: /xyz/openbmc_project/sensors/current/PSU0_IOUTPUT 237: <<: *current entityInstance: 81 multiplierM: 160 path: /xyz/openbmc_project/sensors/current/PSU1_IOUTPUT