Initial commit
This commit is contained in:
+3
@@ -0,0 +1,3 @@
|
||||
{
|
||||
"buses": [0, 1, 2, 8, 10]
|
||||
}
|
||||
@@ -0,0 +1,7 @@
|
||||
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"
|
||||
|
||||
SRC_URI:append = " file://blacklist.json"
|
||||
|
||||
do_install:append () {
|
||||
install -m 0644 -D ${WORKDIR}/blacklist.json ${D}${datadir}/${PN}/blacklist.json
|
||||
}
|
||||
@@ -0,0 +1,33 @@
|
||||
SUMMARY = "YAML configuration for NCPLite"
|
||||
PR = "r1"
|
||||
LICENSE = "Apache-2.0"
|
||||
LIC_FILES_CHKSUM = "file://${COREBASE}/meta/files/common-licenses/Apache-2.0;md5=89aea4e17d99a7cacdbeed46a0096b10"
|
||||
|
||||
inherit allarch
|
||||
|
||||
SRC_URI = " \
|
||||
file://ncplite-ipmi-fru.yaml \
|
||||
file://ncplite-ipmi-fru-properties.yaml \
|
||||
file://ncplite-ipmi-sensors.yaml \
|
||||
file://ncplite-ipmi-inventory-sensors.yaml \
|
||||
"
|
||||
|
||||
S = "${WORKDIR}"
|
||||
|
||||
do_install() {
|
||||
install -m 0644 -D ncplite-ipmi-fru.yaml \
|
||||
${D}${datadir}/${BPN}/ipmi-fru-read.yaml
|
||||
install -m 0644 -D ncplite-ipmi-fru-properties.yaml \
|
||||
${D}${datadir}/${BPN}/ipmi-extra-properties.yaml
|
||||
install -m 0644 -D ncplite-ipmi-sensors.yaml \
|
||||
${D}${datadir}/${BPN}/ipmi-sensors.yaml
|
||||
install -m 0644 -D ncplite-ipmi-inventory-sensors.yaml \
|
||||
${D}${datadir}/${BPN}/ipmi-inventory-sensors.yaml
|
||||
}
|
||||
|
||||
FILES:${PN}-dev = " \
|
||||
${datadir}/${BPN}/ipmi-fru-read.yaml \
|
||||
${datadir}/${BPN}/ipmi-extra-properties.yaml \
|
||||
${datadir}/${BPN}/ipmi-sensors.yaml \
|
||||
${datadir}/${BPN}/ipmi-inventory-sensors.yaml \
|
||||
"
|
||||
+35
@@ -0,0 +1,35 @@
|
||||
/system/chassis/motherboard:
|
||||
xyz.openbmc_project.Inventory.Decorator.Cacheable:
|
||||
Cached: "true"
|
||||
xyz.openbmc_project.Inventory.Decorator.Replaceable:
|
||||
FieldReplaceable: "true"
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
Present: "true"
|
||||
/system:
|
||||
xyz.openbmc_project.Inventory.Decorator.Cacheable:
|
||||
Cached: "true"
|
||||
xyz.openbmc_project.Inventory.Decorator.Replaceable:
|
||||
FieldReplaceable: "true"
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
Present: "true"
|
||||
/system/chassis:
|
||||
xyz.openbmc_project.Inventory.Decorator.Cacheable:
|
||||
Cached: "false"
|
||||
xyz.openbmc_project.Inventory.Decorator.Replaceable:
|
||||
FieldReplaceable: "false"
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
Present: "true"
|
||||
/system/chassis/psu0:
|
||||
xyz.openbmc_project.Inventory.Decorator.Cacheable:
|
||||
Cached: "false"
|
||||
xyz.openbmc_project.Inventory.Decorator.Replaceable:
|
||||
FieldReplaceable: "true"
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
Present: "true"
|
||||
/system/chassis/psu1:
|
||||
xyz.openbmc_project.Inventory.Decorator.Cacheable:
|
||||
Cached: "false"
|
||||
xyz.openbmc_project.Inventory.Decorator.Replaceable:
|
||||
FieldReplaceable: "true"
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
Present: "true"
|
||||
+118
@@ -0,0 +1,118 @@
|
||||
0:
|
||||
/system/chassis:
|
||||
entityID: 23
|
||||
entityInstance: 1
|
||||
interfaces:
|
||||
xyz.openbmc_project.Inventory.Decorator.Asset:
|
||||
Model:
|
||||
IPMIFruProperty: Type
|
||||
IPMIFruSection: Chassis
|
||||
/system/chassis/motherboard:
|
||||
entityID: 7
|
||||
entityInstance: 1
|
||||
interfaces:
|
||||
xyz.openbmc_project.Inventory.Decorator.Asset:
|
||||
BuildDate:
|
||||
IPMIFruProperty: Mfg Date
|
||||
IPMIFruSection: Board
|
||||
Manufacturer:
|
||||
IPMIFruProperty: Manufacturer
|
||||
IPMIFruSection: Board
|
||||
PartNumber:
|
||||
IPMIFruProperty: Part Number
|
||||
IPMIFruSection: Board
|
||||
SerialNumber:
|
||||
IPMIFruProperty: Serial Number
|
||||
IPMIFruSection: Board
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
PrettyName:
|
||||
IPMIFruProperty: Name
|
||||
IPMIFruSection: Board
|
||||
/system:
|
||||
entityID: 7
|
||||
entityInstance: 2
|
||||
interfaces:
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
PrettyName:
|
||||
IPMIFruProperty: Name
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.Asset:
|
||||
Manufacturer:
|
||||
IPMIFruProperty: Manufacturer
|
||||
IPMIFruSection: Product
|
||||
PartNumber:
|
||||
IPMIFruProperty: Model Number
|
||||
IPMIFruSection: Product
|
||||
SerialNumber:
|
||||
IPMIFruProperty: Serial Number
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.Revision:
|
||||
Version:
|
||||
IPMIFruProperty: Version
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.AssetTag:
|
||||
AssetTag:
|
||||
IPMIFruProperty: Asset Tag
|
||||
IPMIFruSection: Product
|
||||
1:
|
||||
/system/chassis/psu0:
|
||||
entityID: 0x13
|
||||
entityInstance: 1
|
||||
interfaces:
|
||||
xyz.openbmc_project.Inventory.Decorator.Asset:
|
||||
Manufacturer:
|
||||
IPMIFruProperty: Manufacturer
|
||||
IPMIFruSection: Product
|
||||
PartNumber:
|
||||
IPMIFruProperty: Model Number
|
||||
IPMIFruSection: Product
|
||||
SerialNumber:
|
||||
IPMIFruProperty: Serial Number
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
PrettyName:
|
||||
IPMIFruProperty: Name
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.Revision:
|
||||
Version:
|
||||
IPMIFruProperty: Version
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.AssetTag:
|
||||
AssetTag:
|
||||
IPMIFruProperty: Asset Tag
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.VendorInformation:
|
||||
CustomField1:
|
||||
IPMIFruProperty: FRU File ID
|
||||
IPMIFruSection: Product
|
||||
2:
|
||||
/system/chassis/psu1:
|
||||
entityID: 0x13
|
||||
entityInstance: 2
|
||||
interfaces:
|
||||
xyz.openbmc_project.Inventory.Decorator.Asset:
|
||||
Manufacturer:
|
||||
IPMIFruProperty: Manufacturer
|
||||
IPMIFruSection: Product
|
||||
PartNumber:
|
||||
IPMIFruProperty: Model Number
|
||||
IPMIFruSection: Product
|
||||
SerialNumber:
|
||||
IPMIFruProperty: Serial Number
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
PrettyName:
|
||||
IPMIFruProperty: Name
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.Revision:
|
||||
Version:
|
||||
IPMIFruProperty: Version
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.AssetTag:
|
||||
AssetTag:
|
||||
IPMIFruProperty: Asset Tag
|
||||
IPMIFruSection: Product
|
||||
xyz.openbmc_project.Inventory.Decorator.VendorInformation:
|
||||
CustomField1:
|
||||
IPMIFruProperty: FRU File ID
|
||||
IPMIFruSection: Product
|
||||
+245
@@ -0,0 +1,245 @@
|
||||
/xyz/openbmc_project/sensors/temperature/TEMP_ENV_FRONT:
|
||||
sensorID: 0xf
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/TEMP_ENV_REAR:
|
||||
sensorID: 0x10
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/TEMP_MAC_ENV:
|
||||
sensorID: 0x11
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/TEMP_MAC_DIE:
|
||||
sensorID: 0x12
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/TEMP_CPU_ENV_2:
|
||||
sensorID: 0x13
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/TEMP_ENV_BMC:
|
||||
sensorID: 0x14
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P3V3_ADC0:
|
||||
sensorID: 0x20
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P1V8_ADC1:
|
||||
sensorID: 0x21
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P1V2_ADC2:
|
||||
sensorID: 0x22
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P1V2_ADC3:
|
||||
sensorID: 0x23
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P0V8_ADC4:
|
||||
sensorID: 0x24
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P0V8_ADC5:
|
||||
sensorID: 0x25
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P1V2_ADC6:
|
||||
sensorID: 0x26
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P0V88_ADC8:
|
||||
sensorID: 0x27
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/P2V5_ADC9:
|
||||
sensorID: 0x28
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/fan_tach/FAN0_RPM:
|
||||
sensorID: 0x30
|
||||
sensorType: 4
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/fan_tach/FAN1_RPM:
|
||||
sensorID: 0x31
|
||||
sensorType: 4
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/fan_tach/FAN2_RPM:
|
||||
sensorID: 0x32
|
||||
sensorType: 4
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/fan_tach/FAN3_RPM:
|
||||
sensorID: 0x33
|
||||
sensorType: 4
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/ALL_PWR_GOOD_H:
|
||||
sensorID: 0x40
|
||||
sensorType: 0x15
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/FAN_STATUS_INT_L:
|
||||
sensorID: 0x41
|
||||
sensorType: 0x15
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/THERMAL_ALERT_L:
|
||||
sensorID: 0x42
|
||||
sensorType: 0x15
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/CPU_CATERR_L:
|
||||
sensorID: 0x43
|
||||
sensorType: 0x7
|
||||
eventReadingType: 0x6f
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/CPU_THERMTEIP_L:
|
||||
sensorID: 0x44
|
||||
sensorType: 0x7
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/PSU0_INT_L:
|
||||
sensorID: 0x45
|
||||
sensorType: 0x9
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/PSU1_INT_L:
|
||||
sensorID: 0x46
|
||||
sensorType: 0x9
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/PSU0_POWER_OK:
|
||||
sensorID: 0x47
|
||||
sensorType: 0x9
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/PSU1_POWER_OK:
|
||||
sensorID: 0x48
|
||||
sensorType: 0x9
|
||||
eventReadingType: 0x03
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/PSU0_PRSNT_L:
|
||||
sensorID: 0x49
|
||||
sensorType: 0x9
|
||||
eventReadingType: 0x08
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/inventory/system/chassis/motherboard/PSU1_PRSNT_L:
|
||||
sensorID: 0x4a
|
||||
sensorType: 0x9
|
||||
eventReadingType: 0x8
|
||||
offset: 0x03
|
||||
/xyz/openbmc_project/sensors/voltage/PSU0_VIN:
|
||||
sensorID: 0x60
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/PSU0_VOUT:
|
||||
sensorID: 0x61
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/current/PSU0_IIN:
|
||||
sensorID: 0x62
|
||||
sensorType: 3
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/current/PSU0_IOUT:
|
||||
sensorID: 0x63
|
||||
sensorType: 3
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/fan_tach/PSU0_FAN1:
|
||||
sensorID: 0x64
|
||||
sensorType: 4
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/PSU0_TEMP1:
|
||||
sensorID: 0x65
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/PSU0_TEMP2:
|
||||
sensorID: 0x66
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/PSU0_TEMP3:
|
||||
sensorID: 0x67
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/PSU1_VIN:
|
||||
sensorID: 0x70
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/voltage/PSU1_VOUT:
|
||||
sensorID: 0x71
|
||||
sensorType: 2
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/current/PSU1_IIN:
|
||||
sensorID: 0x72
|
||||
sensorType: 3
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/current/PSU1_IOUT:
|
||||
sensorID: 0x73
|
||||
sensorType: 3
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/fan_tach/PSU1_FAN1:
|
||||
sensorID: 0x74
|
||||
sensorType: 4
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/PSU1_TEMP1:
|
||||
sensorID: 0x75
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/PSU1_TEMP2:
|
||||
sensorID: 0x76
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/sensors/temperature/PSU1_TEMP3:
|
||||
sensorID: 0x77
|
||||
sensorType: 1
|
||||
eventReadingType: 1
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/watchdog/host0:
|
||||
sensorID: 0xff
|
||||
sensorType: 0x23
|
||||
eventReadingType: 0x6f
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/state/host0:
|
||||
sensorID: 0xff
|
||||
sensorType: 0x09
|
||||
eventReadingType: 0x6f
|
||||
offset: 0xff
|
||||
/xyz/openbmc_project/state/chassis0:
|
||||
sensorID: 0xff
|
||||
sensorType: 0x14
|
||||
eventReadingType: 0x6f
|
||||
offset: 0xff
|
||||
+399
@@ -0,0 +1,399 @@
|
||||
0xf: &temperature
|
||||
entityID: 0x07
|
||||
entityInstance: 0
|
||||
sensorType: 0x01
|
||||
path: /xyz/openbmc_project/sensors/temperature/TEMP_ENV_FRONT
|
||||
sensorReadingType: 0x01
|
||||
multiplierM: 1
|
||||
offsetB: 0
|
||||
bExp: 0
|
||||
rExp: 0
|
||||
unit: xyz.openbmc_project.Sensor.Value.Unit.DegreesC
|
||||
mutability: Mutability::Read
|
||||
serviceInterface: org.freedesktop.DBus.Properties
|
||||
readingType: readingData
|
||||
sensorNamePattern: nameLeaf
|
||||
interfaces:
|
||||
xyz.openbmc_project.Sensor.Value:
|
||||
Value:
|
||||
Offsets:
|
||||
0xFF:
|
||||
type: double
|
||||
|
||||
0x10:
|
||||
<<: *temperature
|
||||
entityInstance: 1
|
||||
path: /xyz/openbmc_project/sensors/temperature/TEMP_ENV_REAR
|
||||
|
||||
0x11:
|
||||
<<: *temperature
|
||||
entityInstance: 2
|
||||
path: /xyz/openbmc_project/sensors/temperature/TEMP_MAC_ENV
|
||||
|
||||
0x12:
|
||||
<<: *temperature
|
||||
entityInstance: 3
|
||||
path: /xyz/openbmc_project/sensors/temperature/TEMP_MAC_DIE
|
||||
|
||||
0x13:
|
||||
<<: *temperature
|
||||
entityInstance: 4
|
||||
path: /xyz/openbmc_project/sensors/temperature/TEMP_CPU_ENV_2
|
||||
|
||||
0x14:
|
||||
<<: *temperature
|
||||
entityInstance: 5
|
||||
path: /xyz/openbmc_project/sensors/temperature/TEMP_ENV_BMC
|
||||
|
||||
0x20: &voltage
|
||||
entityID: 0x07
|
||||
entityInstance: 5
|
||||
sensorType: 0x02
|
||||
path: /xyz/openbmc_project/sensors/voltage/P3V3_ADC0
|
||||
sensorReadingType: 0x01
|
||||
multiplierM: 235
|
||||
offsetB: 0
|
||||
bExp: 0
|
||||
rExp: -4
|
||||
unit: xyz.openbmc_project.Sensor.Value.Unit.Volts
|
||||
mutability: Mutability::Read
|
||||
serviceInterface: org.freedesktop.DBus.Properties
|
||||
readingType: readingData
|
||||
sensorNamePattern: nameLeaf
|
||||
interfaces:
|
||||
xyz.openbmc_project.Sensor.Value:
|
||||
Value:
|
||||
Offsets:
|
||||
0xFF:
|
||||
type: double
|
||||
|
||||
0x21:
|
||||
<<: *voltage
|
||||
entityInstance: 6
|
||||
path: /xyz/openbmc_project/sensors/voltage/P1V8_ADC1
|
||||
multiplierM: 71
|
||||
|
||||
0x22:
|
||||
<<: *voltage
|
||||
entityInstance: 7
|
||||
path: /xyz/openbmc_project/sensors/voltage/P1V2_ADC2
|
||||
multiplierM: 71
|
||||
|
||||
0x23:
|
||||
<<: *voltage
|
||||
entityInstance: 8
|
||||
path: /xyz/openbmc_project/sensors/voltage/P1V2_ADC3
|
||||
multiplierM: 71
|
||||
|
||||
0x24:
|
||||
<<: *voltage
|
||||
entityInstance: 9
|
||||
path: /xyz/openbmc_project/sensors/voltage/P0V8_ADC4
|
||||
multiplierM: 71
|
||||
|
||||
0x25:
|
||||
<<: *voltage
|
||||
entityInstance: 10
|
||||
path: /xyz/openbmc_project/sensors/voltage/P0V8_ADC5
|
||||
multiplierM: 71
|
||||
|
||||
0x26:
|
||||
<<: *voltage
|
||||
entityInstance: 11
|
||||
path: /xyz/openbmc_project/sensors/voltage/P1V2_ADC6
|
||||
multiplierM: 71
|
||||
|
||||
0x27:
|
||||
<<: *voltage
|
||||
entityInstance: 12
|
||||
path: /xyz/openbmc_project/sensors/voltage/P0V88_ADC8
|
||||
multiplierM: 71
|
||||
|
||||
0x28:
|
||||
<<: *voltage
|
||||
entityInstance: 13
|
||||
path: /xyz/openbmc_project/sensors/voltage/P2V5_ADC9
|
||||
multiplierM: 173
|
||||
|
||||
0x30: &fan_tach
|
||||
entityID: 0x0A
|
||||
entityInstance: 0
|
||||
sensorType: 0x04
|
||||
path: /xyz/openbmc_project/sensors/fan_tach/FAN0_RPM
|
||||
sensorReadingType: 0x01
|
||||
multiplierM: 100
|
||||
offsetB: 0
|
||||
bExp: 0
|
||||
rExp: 0
|
||||
unit: xyz.openbmc_project.Sensor.Value.Unit.RPMS
|
||||
mutability: Mutability::Read
|
||||
serviceInterface: org.freedesktop.DBus.Properties
|
||||
readingType: readingData
|
||||
sensorNamePattern: nameLeaf
|
||||
interfaces:
|
||||
xyz.openbmc_project.Sensor.Value:
|
||||
Value:
|
||||
Offsets:
|
||||
255:
|
||||
type: double
|
||||
|
||||
0x31:
|
||||
<<: *fan_tach
|
||||
entityInstance: 1
|
||||
path: /xyz/openbmc_project/sensors/fan_tach/FAN1_RPM
|
||||
|
||||
0x32:
|
||||
<<: *fan_tach
|
||||
entityInstance: 2
|
||||
path: /xyz/openbmc_project/sensors/fan_tach/FAN2_RPM
|
||||
|
||||
0x33:
|
||||
<<: *fan_tach
|
||||
entityInstance: 3
|
||||
path: /xyz/openbmc_project/sensors/fan_tach/FAN3_RPM
|
||||
|
||||
0x40: &discrete
|
||||
entityID: 0x07
|
||||
entityInstance: 16
|
||||
sensorType: 0x15
|
||||
path: /system/chassis/motherboard/ALL_PWR_GOOD_H
|
||||
sensorReadingType: 0x03
|
||||
mutability: Mutability::Read
|
||||
serviceInterface: xyz.openbmc_project.Inventory.Manager
|
||||
readingType: assertion
|
||||
interfaces:
|
||||
xyz.openbmc_project.Inventory.Item:
|
||||
Present:
|
||||
Offsets:
|
||||
0x01:
|
||||
assert: true
|
||||
type: bool
|
||||
0x00:
|
||||
assert: false
|
||||
type: bool
|
||||
|
||||
0x41:
|
||||
<<: *discrete
|
||||
entityID: 0x07
|
||||
entityInstance: 17
|
||||
sensorType: 0x15
|
||||
path: /system/chassis/motherboard/FAN_STATUS_INT_L
|
||||
|
||||
0x42:
|
||||
<<: *discrete
|
||||
entityID: 0x07
|
||||
entityInstance: 18
|
||||
sensorType: 0x15
|
||||
path: /system/chassis/motherboard/THERMAL_ALERT_L
|
||||
|
||||
0x43:
|
||||
<<: *discrete
|
||||
entityID: 0x03
|
||||
entityInstance: 0
|
||||
sensorType: 0x7
|
||||
path: /system/chassis/motherboard/CPU_CATERR_L
|
||||
|
||||
0x44:
|
||||
<<: *discrete
|
||||
entityID: 0x03
|
||||
entityInstance: 1
|
||||
sensorType: 0x7
|
||||
path: /system/chassis/motherboard/CPU_THERMTEIP_L
|
||||
|
||||
0x45:
|
||||
<<: *discrete
|
||||
entityID: 0x13
|
||||
entityInstance: 3
|
||||
sensorType: 0x9
|
||||
path: /system/chassis/motherboard/PSU0_INT_L
|
||||
|
||||
0x46:
|
||||
<<: *discrete
|
||||
entityID: 0x13
|
||||
entityInstance: 4
|
||||
sensorType: 0x9
|
||||
path: /system/chassis/motherboard/PSU1_INT_L
|
||||
|
||||
0x47:
|
||||
<<: *discrete
|
||||
entityID: 0x13
|
||||
entityInstance: 5
|
||||
sensorType: 0x09
|
||||
path: /system/chassis/motherboard/PSU0_POWER_OK
|
||||
|
||||
0x48:
|
||||
<<: *discrete
|
||||
entityID: 0x13
|
||||
entityInstance: 6
|
||||
sensorType: 0x09
|
||||
path: /system/chassis/motherboard/PSU1_POWER_OK
|
||||
|
||||
0x49:
|
||||
<<: *discrete
|
||||
entityID: 0x13
|
||||
entityInstance: 7
|
||||
sensorType: 0x09
|
||||
sensorReadingType: 0x08
|
||||
path: /system/chassis/motherboard/PSU0_PRSNT_L
|
||||
|
||||
0x4a:
|
||||
<<: *discrete
|
||||
entityID: 0x13
|
||||
entityInstance: 8
|
||||
sensorType: 0x09
|
||||
sensorReadingType: 0x08
|
||||
path: /system/chassis/motherboard/PSU1_PRSNT_L
|
||||
|
||||
0x4b:
|
||||
<<: *discrete
|
||||
entityID: 0x7
|
||||
entityInstance: 19
|
||||
sensorType: 0x15
|
||||
path: /system/chassis/motherboard/FAN0_PRSNT_L
|
||||
|
||||
0x4c:
|
||||
<<: *discrete
|
||||
entityID: 0x7
|
||||
entityInstance: 20
|
||||
sensorType: 0x15
|
||||
path: /system/chassis/motherboard/FAN1_PRSNT_L
|
||||
|
||||
0x4d:
|
||||
<<: *discrete
|
||||
entityID: 0x7
|
||||
entityInstance: 21
|
||||
sensorType: 0x15
|
||||
path: /system/chassis/motherboard/FAN2_PRSNT_L
|
||||
|
||||
0x4e:
|
||||
<<: *discrete
|
||||
entityID: 0x7
|
||||
entityInstance: 22
|
||||
sensorType: 0x15
|
||||
path: /system/chassis/motherboard/FAN3_PRSNT_L
|
||||
|
||||
#PSU0 temperature, voltage, fan sensors
|
||||
0x60:
|
||||
<<: *voltage
|
||||
entityID: 0x13
|
||||
entityInstance: 10
|
||||
path: /xyz/openbmc_project/sensors/voltage/PSU0_VIN
|
||||
rExp: 0
|
||||
multiplierM: 1
|
||||
|
||||
0x61:
|
||||
<<: *voltage
|
||||
entityID: 0x13
|
||||
entityInstance: 11
|
||||
path: /xyz/openbmc_project/sensors/voltage/PSU0_VOUT
|
||||
rExp: -2
|
||||
multiplierM: 5
|
||||
|
||||
0x62: ¤t
|
||||
entityID: 0x13
|
||||
entityInstance: 12
|
||||
sensorType: 0x03
|
||||
path: /xyz/openbmc_project/sensors/current/PSU0_IIN
|
||||
sensorReadingType: 0x01
|
||||
multiplierM: 16
|
||||
offsetB: 0
|
||||
bExp: 0
|
||||
rExp: -3
|
||||
unit: xyz.openbmc_project.Sensor.Value.Unit.Amperes
|
||||
mutability: Mutability::Read
|
||||
serviceInterface: org.freedesktop.DBus.Properties
|
||||
readingType: readingData
|
||||
sensorNamePattern: nameLeaf
|
||||
interfaces:
|
||||
xyz.openbmc_project.Sensor.Value:
|
||||
Value:
|
||||
Offsets:
|
||||
0xFF:
|
||||
type: double
|
||||
|
||||
0x63:
|
||||
<<: *current
|
||||
entityID: 0x13
|
||||
entityInstance: 13
|
||||
path: /xyz/openbmc_project/sensors/current/PSU0_IOUT
|
||||
multiplierM: 70
|
||||
rExp: -2
|
||||
|
||||
0x64:
|
||||
<<: *fan_tach
|
||||
entityID: 0x13
|
||||
entityInstance: 14
|
||||
path: /xyz/openbmc_project/sensors/fan_tach/PSU0_FAN1
|
||||
|
||||
0x65:
|
||||
<<: *temperature
|
||||
entityID: 0x13
|
||||
entityInstance: 15
|
||||
path: /xyz/openbmc_project/sensors/temperature/PSU0_TEMP1
|
||||
|
||||
0x66:
|
||||
<<: *temperature
|
||||
entityID: 0x13
|
||||
entityInstance: 16
|
||||
path: /xyz/openbmc_project/sensors/temperature/PSU0_TEMP2
|
||||
|
||||
0x67:
|
||||
<<: *temperature
|
||||
entityID: 0x13
|
||||
entityInstance: 17
|
||||
path: /xyz/openbmc_project/sensors/temperature/PSU0_TEMP3
|
||||
|
||||
#PSU1 temperature, voltage, fan sensors
|
||||
0x70:
|
||||
<<: *voltage
|
||||
entityID: 0x13
|
||||
entityInstance: 18
|
||||
path: /xyz/openbmc_project/sensors/voltage/PSU1_VIN
|
||||
rExp: 0
|
||||
multiplierM: 1
|
||||
|
||||
0x71:
|
||||
<<: *voltage
|
||||
entityID: 0x13
|
||||
entityInstance: 19
|
||||
path: /xyz/openbmc_project/sensors/voltage/PSU1_VOUT
|
||||
rExp: -2
|
||||
multiplierM: 5
|
||||
|
||||
0x72:
|
||||
<<: *current
|
||||
entityID: 0x13
|
||||
entityInstance: 20
|
||||
path: /xyz/openbmc_project/sensors/current/PSU1_IIN
|
||||
|
||||
0x73:
|
||||
<<: *current
|
||||
entityID: 0x13
|
||||
entityInstance: 21
|
||||
path: /xyz/openbmc_project/sensors/current/PSU1_IOUT
|
||||
multiplierM: 70
|
||||
rExp: -2
|
||||
|
||||
0x74:
|
||||
<<: *fan_tach
|
||||
entityID: 0x13
|
||||
entityInstance: 22
|
||||
path: /xyz/openbmc_project/sensors/fan_tach/PSU1_FAN1
|
||||
|
||||
0x75:
|
||||
<<: *temperature
|
||||
entityID: 0x13
|
||||
entityInstance: 23
|
||||
path: /xyz/openbmc_project/sensors/temperature/PSU1_TEMP1
|
||||
|
||||
0x76:
|
||||
<<: *temperature
|
||||
entityID: 0x13
|
||||
entityInstance: 24
|
||||
path: /xyz/openbmc_project/sensors/temperature/PSU1_TEMP2
|
||||
|
||||
0x77:
|
||||
<<: *temperature
|
||||
entityID: 0x13
|
||||
entityInstance: 25
|
||||
path: /xyz/openbmc_project/sensors/temperature/PSU1_TEMP3
|
||||
@@ -0,0 +1 @@
|
||||
baud = 115200
|
||||
@@ -0,0 +1,28 @@
|
||||
#!/bin/bash
|
||||
|
||||
function usage()
|
||||
{
|
||||
echo "Usage: $(basename "$0") init|reset"
|
||||
}
|
||||
|
||||
if [ "$#" -ne "1" ] ; then
|
||||
usage
|
||||
exit 1;
|
||||
fi
|
||||
|
||||
UART_ROUTING_SYSFS="/sys/bus/platform/drivers/aspeed-uart-routing/1e789098.uart-routing"
|
||||
|
||||
case "$1" in
|
||||
init)
|
||||
echo -n "uart1" > ${UART_ROUTING_SYSFS}/uart4
|
||||
echo -n "uart4" > ${UART_ROUTING_SYSFS}/uart1
|
||||
;;
|
||||
reset)
|
||||
echo -n "io1" > ${UART_ROUTING_SYSFS}/uart1
|
||||
echo -n "io4" > ${UART_ROUTING_SYSFS}/uart4
|
||||
;;
|
||||
*)
|
||||
usage
|
||||
exit 1;
|
||||
;;
|
||||
esac
|
||||
@@ -0,0 +1,5 @@
|
||||
[Service]
|
||||
ExecStartPre=/usr/sbin/uart-routing.sh init
|
||||
ExecStart=-/usr/sbin/dropbear -r ${DROPBEAR_RSAKEY_DIR}/dropbear_rsa_host_key -c "/usr/bin/obmc-console-client" -i $DROPBEAR_EXTRA_ARGS
|
||||
ExecStopPost=/usr/sbin/uart-routing.sh reset
|
||||
StandardInput=socket
|
||||
@@ -0,0 +1,17 @@
|
||||
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"
|
||||
|
||||
SRC_URI:append = " file://uart-routing.sh \
|
||||
file://use-socket.conf.in \
|
||||
"
|
||||
|
||||
RDEPENDS:${PN}:append = " bash"
|
||||
|
||||
OBMC_CONSOLE_HOST_TTY:ncplite = "ttyS3"
|
||||
|
||||
do_install:append() {
|
||||
install -d ${D}${sbindir}
|
||||
install -m 0755 ${WORKDIR}/uart-routing.sh -D ${D}${sbindir}/uart-routing.sh
|
||||
|
||||
install -d ${D}${systemd_system_unitdir}
|
||||
install -m 0755 ${WORKDIR}/use-socket.conf.in -D ${D}${systemd_system_unitdir}/obmc-console-ssh@.service.d/use-socket.conf
|
||||
}
|
||||
@@ -0,0 +1,177 @@
|
||||
{
|
||||
"sensors": [
|
||||
{
|
||||
"name": "FAN0_RPM",
|
||||
"type": "fan",
|
||||
"readPath": "/xyz/openbmc_project/sensors/fan_tach/FAN0_RPM",
|
||||
"writePath": "/sys/devices/platform/pwm-fan0/hwmon/**/pwm1",
|
||||
"ignoreDbusMinMax": true,
|
||||
"min": 0,
|
||||
"max": 255
|
||||
},
|
||||
{
|
||||
"name": "FAN1_RPM",
|
||||
"type": "fan",
|
||||
"readPath": "/xyz/openbmc_project/sensors/fan_tach/FAN1_RPM",
|
||||
"writePath": "/sys/devices/platform/pwm-fan0/hwmon/**/pwm1",
|
||||
"ignoreDbusMinMax": true,
|
||||
"min": 0,
|
||||
"max": 255
|
||||
},
|
||||
{
|
||||
"name": "FAN2_RPM",
|
||||
"type": "fan",
|
||||
"readPath": "/xyz/openbmc_project/sensors/fan_tach/FAN2_RPM",
|
||||
"writePath": "/sys/devices/platform/pwm-fan1/hwmon/**/pwm1",
|
||||
"ignoreDbusMinMax": true,
|
||||
"min": 0,
|
||||
"max": 255
|
||||
},
|
||||
{
|
||||
"name": "FAN3_RPM",
|
||||
"type": "fan",
|
||||
"readPath": "/xyz/openbmc_project/sensors/fan_tach/FAN3_RPM",
|
||||
"writePath": "/sys/devices/platform/pwm-fan1/hwmon/**/pwm1",
|
||||
"ignoreDbusMinMax": true,
|
||||
"min": 0,
|
||||
"max": 255
|
||||
},
|
||||
{
|
||||
"name": "TEMP_MAC_ENV",
|
||||
"type": "temp",
|
||||
"readPath": "/xyz/openbmc_project/sensors/temperature/TEMP_MAC_ENV",
|
||||
"writePath": "",
|
||||
"min": 0,
|
||||
"max": 0,
|
||||
"ignoreDbusMinMax": true,
|
||||
"timeout": 0
|
||||
},
|
||||
{
|
||||
"name": "TEMP_MAC_DIE",
|
||||
"type": "temp",
|
||||
"readPath": "/xyz/openbmc_project/sensors/temperature/TEMP_MAC_DIE",
|
||||
"writePath": "",
|
||||
"min": 0,
|
||||
"max": 0,
|
||||
"ignoreDbusMinMax": true,
|
||||
"timeout": 0
|
||||
}
|
||||
],
|
||||
"zones": [
|
||||
{
|
||||
"id": 1,
|
||||
"minThermalOutput": 0.0,
|
||||
"failsafePercent": 100.0,
|
||||
"pids": [
|
||||
{
|
||||
"name": "FAN0_RPM",
|
||||
"type": "fan",
|
||||
"inputs": ["FAN0_RPM"],
|
||||
"setpoint": 30.0,
|
||||
"pid": {
|
||||
"samplePeriod": 1.0,
|
||||
"proportionalCoeff": 0.0,
|
||||
"integralCoeff": 0.0,
|
||||
"derivativeCoeff": 0.0,
|
||||
"feedFwdOffsetCoeff": 0.0,
|
||||
"feedFwdGainCoeff": 1.0,
|
||||
"integralLimit_min": 0.0,
|
||||
"integralLimit_max": 0.0,
|
||||
"outLim_min": 0.0,
|
||||
"outLim_max": 100.0,
|
||||
"slewNeg": 0.0,
|
||||
"slewPos": 0.0
|
||||
}
|
||||
},
|
||||
{
|
||||
"name": "FAN1_RPM",
|
||||
"type": "fan",
|
||||
"inputs": ["FAN1_RPM"],
|
||||
"setpoint": 30.0,
|
||||
"pid": {
|
||||
"samplePeriod": 1.0,
|
||||
"proportionalCoeff": 0.0,
|
||||
"integralCoeff": 0.0,
|
||||
"derivativeCoeff": 0.0,
|
||||
"feedFwdOffsetCoeff": 0.0,
|
||||
"feedFwdGainCoeff": 1.0,
|
||||
"integralLimit_min": 0.0,
|
||||
"integralLimit_max": 0.0,
|
||||
"outLim_min": 0.0,
|
||||
"outLim_max": 100.0,
|
||||
"slewNeg": 0.0,
|
||||
"slewPos": 0.0
|
||||
}
|
||||
},
|
||||
{
|
||||
"name": "FAN2_RPM",
|
||||
"type": "fan",
|
||||
"inputs": ["FAN2_RPM"],
|
||||
"setpoint": 30.0,
|
||||
"pid": {
|
||||
"samplePeriod": 1.0,
|
||||
"proportionalCoeff": 0.0,
|
||||
"integralCoeff": 0.0,
|
||||
"derivativeCoeff": 0.0,
|
||||
"feedFwdOffsetCoeff": 0.0,
|
||||
"feedFwdGainCoeff": 1.0,
|
||||
"integralLimit_min": 0.0,
|
||||
"integralLimit_max": 0.0,
|
||||
"outLim_min": 0.0,
|
||||
"outLim_max": 100.0,
|
||||
"slewNeg": 0.0,
|
||||
"slewPos": 0.0
|
||||
}
|
||||
},
|
||||
{
|
||||
"name": "FAN3_RPM",
|
||||
"type": "fan",
|
||||
"inputs": ["FAN3_RPM"],
|
||||
"setpoint": 30.0,
|
||||
"pid": {
|
||||
"samplePeriod": 1.0,
|
||||
"proportionalCoeff": 0.0,
|
||||
"integralCoeff": 0.0,
|
||||
"derivativeCoeff": 0.0,
|
||||
"feedFwdOffsetCoeff": 0.0,
|
||||
"feedFwdGainCoeff": 1.0,
|
||||
"integralLimit_min": 0.0,
|
||||
"integralLimit_max": 0.0,
|
||||
"outLim_min": 0.0,
|
||||
"outLim_max": 100.0,
|
||||
"slewNeg": 0.0,
|
||||
"slewPos": 0.0
|
||||
}
|
||||
},
|
||||
{
|
||||
"name": "TEMP_MAC_DIE",
|
||||
"type": "stepwise",
|
||||
"inputs": ["TEMP_MAC_DIE"],
|
||||
"setpoint": 30.0,
|
||||
"pid": {
|
||||
"samplePeriod": 1.0,
|
||||
"positiveHysteresis": 1.0,
|
||||
"negativeHysteresis": 1.0,
|
||||
"isCeiling": false,
|
||||
"reading": {
|
||||
"0": 25,
|
||||
"1": 40,
|
||||
"2": 50,
|
||||
"3": 60,
|
||||
"4": 70,
|
||||
"5": 80
|
||||
},
|
||||
"output": {
|
||||
"0": 45,
|
||||
"1": 60,
|
||||
"2": 75,
|
||||
"3": 85,
|
||||
"4": 90,
|
||||
"5": 100
|
||||
}
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
}
|
||||
@@ -0,0 +1,10 @@
|
||||
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"
|
||||
|
||||
SRC_URI:append = " file://config.json"
|
||||
|
||||
FILES:${PN}:append = " ${datadir}/swampd/config.json"
|
||||
|
||||
do_install:append:ncplite() {
|
||||
install -d ${D}${datadir}/swampd
|
||||
install -m 0644 -D ${WORKDIR}/config.json ${D}${datadir}/swampd/config.json
|
||||
}
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/ALL_PWR_GOOD_H
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=172
|
||||
NAME=ALL_PWR_GOOD_H
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/FAN_STATUS_INT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=98
|
||||
NAME=FAN_STATUS_INT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/PSU1_PRSNT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=47
|
||||
NAME=PSU1_PRSNT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/FAN0_PRSNT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-polled-event
|
||||
KEY=2
|
||||
NAME=FAN0_PRSNT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/FAN1_PRSNT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-polled-event
|
||||
KEY=6
|
||||
NAME=FAN1_PRSNT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/FAN2_PRSNT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-polled-event
|
||||
KEY=10
|
||||
NAME=FAN2_PRSNT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/FAN3_PRSNT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-polled-event
|
||||
KEY=14
|
||||
NAME=FAN3_PRSNT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/THERMAL_ALERT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=122
|
||||
NAME=THERMAL_ALERT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/CPU_CATERR_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=107
|
||||
NAME=CPU_CATERR_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/CPU_THERMTEIP_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=173
|
||||
NAME=CPU_THERMTEIP_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/PSU0_INT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=169
|
||||
NAME=PSU0_INT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/PSU1_INT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=170
|
||||
NAME=PSU1_INT_L
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/PSU0_POWER_OK
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=100
|
||||
NAME=PSU0_POWER_OK
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/PSU1_POWER_OK
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=101
|
||||
NAME=PSU1_POWER_OK
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
INVENTORY=/system/chassis/motherboard/PSU0_PRSNT_L
|
||||
DEVPATH=/dev/input/by-path/platform-gpio-keys-event
|
||||
KEY=46
|
||||
NAME=PSU0_PRSNT_L
|
||||
+13
@@ -0,0 +1,13 @@
|
||||
[Unit]
|
||||
Description=Phosphor GPIO %I Presence
|
||||
Wants=mapper-wait@-xyz-openbmc_project-inventory.service
|
||||
After=mapper-wait@-xyz-openbmc_project-inventory.service
|
||||
ConditionPathExists={envfiledir}/obmc/gpio/gpio-%i.conf
|
||||
|
||||
[Service]
|
||||
EnvironmentFile={envfiledir}/obmc/gpio/gpio-%i.conf
|
||||
ExecStart=/usr/bin/phosphor-gpio-presence --path=${{DEVPATH}} --inventory=${{INVENTORY}} --key=${{KEY}} --name=${{NAME}}
|
||||
SyslogIdentifier=phosphor-gpio-presence
|
||||
|
||||
[Install]
|
||||
RequiredBy=multi-user.target
|
||||
@@ -0,0 +1,12 @@
|
||||
FILESEXTRAPATHS:append:ncplite := "${THISDIR}/${PN}:"
|
||||
|
||||
NCPLITE_OBMC_GPIO_INSTANCES = "0 1 2 3 4 5 6 7 8 9 10 11 12 13 14"
|
||||
NCPLITE_OBMC_GPIO_ENV_FMT = "obmc/gpio/gpio-{0}.conf"
|
||||
|
||||
TMPL = "phosphor-gpio-presence@.service"
|
||||
INSTFMT = "phosphor-gpio-presence@{0}.service"
|
||||
TGT = "multi-user.target"
|
||||
FMT = "../${TMPL}:${TGT}.requires/${INSTFMT}"
|
||||
|
||||
SYSTEMD_LINK:${PN}-presence:append:ncplite = " ${@compose_list(d, 'FMT', 'NCPLITE_OBMC_GPIO_INSTANCES')}"
|
||||
SYSTEMD_ENVIRONMENT_FILE:${PN}-presence:append:ncplite = " ${@compose_list(d, 'NCPLITE_OBMC_GPIO_ENV_FMT', 'NCPLITE_OBMC_GPIO_INSTANCES')}"
|
||||
@@ -0,0 +1,5 @@
|
||||
OBMC_IMAGE_EXTRA_INSTALL:append = " \
|
||||
ipmitool \
|
||||
usbutils \
|
||||
ethtool \
|
||||
"
|
||||
@@ -0,0 +1,4 @@
|
||||
EXTRA_OEMESON:append = " \
|
||||
-Dredfish-dbus-log=enabled \
|
||||
-Dkvm=disabled \
|
||||
"
|
||||
@@ -0,0 +1,17 @@
|
||||
SUMMARY = "Copy the inventory cleanup yaml for inventory manager"
|
||||
PR = "r1"
|
||||
LICENSE = "Apache-2.0"
|
||||
LIC_FILES_CHKSUM = "file://${COREBASE}/meta/files/common-licenses/Apache-2.0;md5=89aea4e17d99a7cacdbeed46a0096b10"
|
||||
|
||||
inherit allarch
|
||||
inherit phosphor-inventory-manager
|
||||
|
||||
S = "${WORKDIR}"
|
||||
|
||||
SRC_URI = "file://inventory-cleanup.yaml"
|
||||
|
||||
do_install() {
|
||||
install -D inventory-cleanup.yaml ${D}${base_datadir}/events.d/inventory-cleanup.yaml
|
||||
}
|
||||
|
||||
FILES:${PN} += "${base_datadir}/events.d/inventory-cleanup.yaml"
|
||||
+16
@@ -0,0 +1,16 @@
|
||||
description: >
|
||||
NCPLITE inventory fixups
|
||||
|
||||
events:
|
||||
- name: Add Chassis interface
|
||||
description: >
|
||||
Add the chassis interface on the chassis inventory path
|
||||
type: startup
|
||||
actions:
|
||||
- name: createObjects
|
||||
objs:
|
||||
/system/chassis:
|
||||
xyz.openbmc_project.Inventory.Item.Chassis:
|
||||
Type:
|
||||
value: "xyz.openbmc_project.Inventory.Item.Chassis.ChassisType.RackMount"
|
||||
type: string
|
||||
@@ -0,0 +1 @@
|
||||
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"
|
||||
@@ -0,0 +1,8 @@
|
||||
{
|
||||
"id": 32,
|
||||
"revision": 1,
|
||||
"addn_dev_support": 143,
|
||||
"manuf_id": 51242,
|
||||
"prod_id": 9600,
|
||||
"aux": 0
|
||||
}
|
||||
+17
@@ -0,0 +1,17 @@
|
||||
[Unit]
|
||||
Description=Read %I EEPROM
|
||||
Wants=mapper-wait@-xyz-openbmc_project-inventory.service
|
||||
After=mapper-wait@-xyz-openbmc_project-inventory.service
|
||||
StartLimitInterval=120
|
||||
StartLimitBurst=10
|
||||
|
||||
[Service]
|
||||
Restart=on-failure
|
||||
RestartSec=10
|
||||
EnvironmentFile={envfiledir}/obmc/eeproms/%I
|
||||
ExecStartPre={bindir}/of-name-to-eeprom.sh {envfiledir}/obmc/eeproms/%I
|
||||
ExecStart=/usr/bin/env phosphor-read-eeprom --eeprom $SYSFS_PATH --fruid $FRUID
|
||||
SyslogIdentifier=phosphor-read-eeprom
|
||||
|
||||
[Install]
|
||||
WantedBy=multi-user.target
|
||||
+2
@@ -0,0 +1,2 @@
|
||||
SYSFS_PATH=/sys/bus/i2c/devices/3-0050/eeprom
|
||||
FRUID=0
|
||||
+2
@@ -0,0 +1,2 @@
|
||||
SYSFS_PATH=/sys/bus/i2c/devices/4-0050/eeprom
|
||||
FRUID=1
|
||||
+2
@@ -0,0 +1,2 @@
|
||||
SYSFS_PATH=/sys/bus/i2c/devices/5-0050/eeprom
|
||||
FRUID=2
|
||||
@@ -0,0 +1,34 @@
|
||||
inherit obmc-phosphor-systemd
|
||||
|
||||
DEPENDS:append:ncplite = " ncplite-yaml-config"
|
||||
|
||||
FILESEXTRAPATHS:prepend:ncplite := "${THISDIR}/${PN}:"
|
||||
|
||||
SRC_URI:append:ncplite = " file://ncplite-obmc-read-eeprom@.service \
|
||||
"
|
||||
|
||||
|
||||
IPMI_FRU_YAML:ncplite="${STAGING_DIR_HOST}${datadir}/ncplite-yaml-config/ipmi-fru-read.yaml"
|
||||
IPMI_FRU_PROP_YAML:ncplite="${STAGING_DIR_HOST}${datadir}/ncplite-yaml-config/ipmi-extra-properties.yaml"
|
||||
|
||||
EEPROM_NAMES = "motherboard psu1 psu0"
|
||||
|
||||
EEPROMFMT = "system/chassis/{0}"
|
||||
EEPROM_ESCAPEDFMT = "system-chassis-{0}"
|
||||
EEPROMS = "${@compose_list(d, 'EEPROMFMT', 'EEPROM_NAMES')}"
|
||||
EEPROMS_ESCAPED = "${@compose_list(d, 'EEPROM_ESCAPEDFMT', 'EEPROM_NAMES')}"
|
||||
|
||||
ENVFMT = "obmc/eeproms/{0}"
|
||||
SYSTEMD_ENVIRONMENT_FILE:${PN}:append:ncplite := " ${@compose_list(d, 'ENVFMT', 'EEPROMS')}"
|
||||
|
||||
TMPL = "obmc-read-eeprom@.service"
|
||||
TGT = "multi-user.target"
|
||||
INSTFMT = "obmc-read-eeprom@{0}.service"
|
||||
FMT = "../${TMPL}:${TGT}.wants/${INSTFMT}"
|
||||
|
||||
SYSTEMD_LINK:${PN}:append:ncplite := " ${@compose_list(d, 'FMT', 'EEPROMS_ESCAPED')}"
|
||||
|
||||
do_install:append:ncplite() {
|
||||
install -d ${D}${systemd_system_unitdir}
|
||||
install -m 0644 ${WORKDIR}/ncplite-obmc-read-eeprom@.service ${D}${systemd_system_unitdir}/obmc-read-eeprom@.service
|
||||
}
|
||||
+4
@@ -0,0 +1,4 @@
|
||||
#!/bin/bash
|
||||
|
||||
echo "Ufi_Bmc: Trigger soft off the host"
|
||||
exit 0
|
||||
+13
@@ -0,0 +1,13 @@
|
||||
[Unit]
|
||||
Description=Soft power off of the host
|
||||
Wants=obmc-host-stop-pre@0.target
|
||||
Before=obmc-host-stop-pre@0.target
|
||||
Conflicts=obmc-host-start@0.target
|
||||
ConditionPathExists=!/run/openbmc/host@0-request
|
||||
ConditionPathExists=!/lib/systemd/system/pldmSoftPowerOff.service
|
||||
|
||||
[Service]
|
||||
Restart=no
|
||||
ExecStart=/usr/bin/env phosphor-softpoweroff
|
||||
SyslogIdentifier=phosphor-softpoweroff
|
||||
Type=oneshot
|
||||
@@ -0,0 +1,20 @@
|
||||
FILESEXTRAPATHS:append:ncplite := "${THISDIR}/${PN}:"
|
||||
|
||||
DEPENDS:append:ncplite = " ncplite-yaml-config"
|
||||
|
||||
EXTRA_OEMESON:ncplite = " \
|
||||
-Dsensor-yaml-gen=${STAGING_DIR_HOST}${datadir}/ncplite-yaml-config/ipmi-sensors.yaml \
|
||||
-Dfru-yaml-gen=${STAGING_DIR_HOST}${datadir}/ncplite-yaml-config/ipmi-fru-read.yaml \
|
||||
-Dinvsensor-yaml-gen=${STAGING_DIR_HOST}${datadir}/ncplite-yaml-config/ipmi-inventory-sensors.yaml \
|
||||
"
|
||||
|
||||
RDEPENDS:${PN} += "bash"
|
||||
|
||||
SRC_URI += "file://phosphor-softpoweroff \
|
||||
file://xyz.openbmc_project.Ipmi.Internal.SoftPowerOff.service \
|
||||
"
|
||||
|
||||
do_install:append:ncplite (){
|
||||
install -m 0755 ${WORKDIR}/phosphor-softpoweroff ${D}/${bindir}/phosphor-softpoweroff
|
||||
install -m 0644 ${WORKDIR}/${SOFT_SVC} ${D}${systemd_unitdir}/system/${SOFT_SVC}
|
||||
}
|
||||
@@ -0,0 +1,18 @@
|
||||
SUMMARY = "Phosphor LED Group Management for NCPLite"
|
||||
PR = "r1"
|
||||
LICENSE = "Apache-2.0"
|
||||
LIC_FILES_CHKSUM = "file://${COREBASE}/meta/files/common-licenses/Apache-2.0;md5=89aea4e17d99a7cacdbeed46a0096b10"
|
||||
|
||||
inherit native
|
||||
|
||||
PROVIDES += "virtual/phosphor-led-manager-config-native"
|
||||
|
||||
SRC_URI += "file://led.yaml"
|
||||
S = "${WORKDIR}"
|
||||
|
||||
# Copies example led layout yaml file
|
||||
do_install() {
|
||||
SRC=${S}
|
||||
DEST=${D}${datadir}/phosphor-led-manager
|
||||
install -D ${SRC}/led.yaml ${DEST}/led.yaml
|
||||
}
|
||||
@@ -0,0 +1,19 @@
|
||||
bmc_booted:
|
||||
|
||||
power_on:
|
||||
|
||||
fan0_good:
|
||||
|
||||
fan0_fault:
|
||||
|
||||
fan1_good:
|
||||
|
||||
fan1_fault:
|
||||
|
||||
fan2_good:
|
||||
|
||||
fan2_fault:
|
||||
|
||||
fan3_good:
|
||||
|
||||
fan3_fault:
|
||||
@@ -0,0 +1 @@
|
||||
ERR_INFO_CAP = "256"
|
||||
+7
@@ -0,0 +1,7 @@
|
||||
RDEPENDS:${PN}-inventory:append:ncplite = " phosphor-gpio-monitor-presence"
|
||||
RDEPENDS:${PN}-chassis-state-mgmt:append:ncplite = " phosphor-state-manager-ncplite"
|
||||
RDEPENDS:${PN}-extras:append:ncplite = " entity-manager \
|
||||
dbus-sensors \
|
||||
ncplite-inventory-log \
|
||||
ncplite-led \
|
||||
"
|
||||
@@ -0,0 +1 @@
|
||||
PACKAGECONFIG:append:ncplite = " log-threshold log-watchdog log-alarm send-to-logger"
|
||||
@@ -0,0 +1 @@
|
||||
PACKAGECONFIG:remove = " intrusionsensor ipmbsensor external nvmesensor"
|
||||
+21
@@ -0,0 +1,21 @@
|
||||
/xyz/openbmc_project/ipmi/sol/eth0:
|
||||
- Interface: xyz.openbmc_project.Ipmi.SOL
|
||||
Properties:
|
||||
Enable:
|
||||
Default: 'true'
|
||||
Privilege:
|
||||
Default: 4
|
||||
Progress:
|
||||
Default: 0
|
||||
RetryCount:
|
||||
Default: 7
|
||||
RetryIntervalMS:
|
||||
Default: 100
|
||||
Threshold:
|
||||
Default: 1
|
||||
|
||||
/xyz/openbmc_project/control/host0/power_restore_policy:
|
||||
- Interface: xyz.openbmc_project.Control.Power.RestorePolicy
|
||||
Properties:
|
||||
PowerRestorePolicy:
|
||||
Default: RestorePolicy::Policy::AlwaysOn
|
||||
+2
@@ -0,0 +1,2 @@
|
||||
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"
|
||||
SRC_URI:append:ncplite = " file://ncplite_settings.override.yml"
|
||||
@@ -0,0 +1,17 @@
|
||||
{
|
||||
"gpio_configs": {
|
||||
"power_config": {
|
||||
"power_good_in": "CPU_PWRGD",
|
||||
"power_up_outs": [],
|
||||
"reset_outs": []
|
||||
}
|
||||
},
|
||||
|
||||
"gpio_definitions": [
|
||||
{
|
||||
"name": "CPU_PWRGD",
|
||||
"pin": "F0",
|
||||
"direction": "in"
|
||||
}
|
||||
]
|
||||
}
|
||||
@@ -0,0 +1 @@
|
||||
FILESEXTRAPATHS:prepend:ncplite := "${THISDIR}/${PN}:"
|
||||
@@ -0,0 +1,3 @@
|
||||
PACKAGECONFIG:append = " smbios-ipmi-blob"
|
||||
|
||||
PACKAGECONFIG:remove = " cpuinfo"
|
||||
+59
@@ -0,0 +1,59 @@
|
||||
#!/bin/bash
|
||||
|
||||
# Usage of this utility
|
||||
usage() {
|
||||
echo "Usage: $(basename "$0") [on|off|forceoff]";
|
||||
}
|
||||
|
||||
#Check CPU boot done pin drop in 30s
|
||||
timeout=30
|
||||
wait_graceful_off(){
|
||||
echo "Wait for host shutdown in ${timeout}s"
|
||||
while [ "${timeout}" -gt 0 ]; do
|
||||
host_state=$(gpioget --numeric host0-ready)
|
||||
timeout=$((timeout-1))
|
||||
if [ "${host_state}" -eq 0 ]; then
|
||||
echo "Host is graceful off"
|
||||
return 0
|
||||
fi
|
||||
sleep 1
|
||||
done
|
||||
echo "Host still on, but reach timeout"
|
||||
}
|
||||
|
||||
set_gpio_power_off() {
|
||||
echo "Set GPIO to power off chassis"
|
||||
gpioset --hold-period 50ms -t0 power-chassis-control0=1
|
||||
gpioset --hold-period 50ms -t0 power-chassis-control1=1
|
||||
}
|
||||
|
||||
set_gpio_power_on() {
|
||||
echo "Set GPIO to power on chassis"
|
||||
val=$(gpioget --numeric host0-ready)
|
||||
if [ "$val" == 1 ]; then
|
||||
exit 0
|
||||
fi
|
||||
|
||||
gpioset --hold-period 50ms -t0 power-chassis-control0=0
|
||||
gpioset --hold-period 50ms -t0 power-chassis-control1=0
|
||||
|
||||
#Record IPMI power cycle SEL
|
||||
busctl call xyz.openbmc_project.Logging.IPMI \
|
||||
/xyz/openbmc_project/Logging/IPMI \
|
||||
xyz.openbmc_project.Logging.IPMI IpmiSelAdd ssaybq \
|
||||
"Power Cycle" "/xyz/openbmc_project/state/host0" \
|
||||
3 0x01 0xff 0xff true 0x0020
|
||||
}
|
||||
|
||||
if [ "$1" == "on" ]; then
|
||||
set_gpio_power_on
|
||||
elif [ "$1" == "off" ]; then
|
||||
wait_graceful_off
|
||||
set_gpio_power_off
|
||||
elif [ "$1" == "forceoff" ]; then
|
||||
set_gpio_power_off
|
||||
else
|
||||
echo "Invalid parameter"
|
||||
usage
|
||||
fi
|
||||
exit 0
|
||||
@@ -0,0 +1,32 @@
|
||||
#!/bin/bash
|
||||
|
||||
# Usage of this utility
|
||||
usage() {
|
||||
echo "Usage: $(basename "$0") [reset|gracefuloff]"
|
||||
}
|
||||
|
||||
graceful_off() {
|
||||
echo "Set GPIO to graceful shutdown Host"
|
||||
gpioset --hold-period 50ms -t0 power-button=1
|
||||
sleep 0.1
|
||||
gpioset --hold-period 50ms -t0 power-button=0
|
||||
gpioget power-button >/dev/null 2>&1
|
||||
}
|
||||
|
||||
force_reset() {
|
||||
echo "Set GPIO to reset Host"
|
||||
gpioset --hold-period 50ms -t0 reset-button=0
|
||||
sleep 0.1
|
||||
gpioset --hold-period 50ms -t0 reset-button=1
|
||||
gpioget reset-button >/dev/null 2>&1
|
||||
}
|
||||
|
||||
if [ "$1" == "reset" ]; then
|
||||
force_reset
|
||||
elif [ "$1" == "gracefuloff" ]; then
|
||||
graceful_off
|
||||
else
|
||||
echo "Invalid parameter"
|
||||
usage
|
||||
fi
|
||||
exit 0
|
||||
+15
@@ -0,0 +1,15 @@
|
||||
[Unit]
|
||||
Description=NCPLite Chassis Power Off
|
||||
Before=phosphor-wait-power-off@%i.service
|
||||
Conflicts=ncplite-chassis-poweron@%i.target
|
||||
|
||||
[Service]
|
||||
Type=oneshot
|
||||
ExecStart=@SBINDIR@/chassis-control off
|
||||
ExecStartPost=/bin/sh -c "busctl call xyz.openbmc_project.Logging.IPMI \
|
||||
/xyz/openbmc_project/Logging/IPMI \
|
||||
xyz.openbmc_project.Logging.IPMI IpmiSelAdd ssaybq \
|
||||
'Power Off' '/xyz/openbmc_project/state/host0' \
|
||||
3 0x00 0xff 0xff true 0x0020"
|
||||
ExecStartPost=/bin/sleep 10
|
||||
SyslogIdentifier=chassis-control
|
||||
+10
@@ -0,0 +1,10 @@
|
||||
[Unit]
|
||||
Description=NCPLite Chassis Power on
|
||||
Before=phosphor-wait-power-on@%i.service
|
||||
After=obmc-power-start-pre@%i.target
|
||||
Conflicts=ncplite-chassis-poweroff@%i.target
|
||||
|
||||
[Service]
|
||||
Type=oneshot
|
||||
ExecStart=@SBINDIR@/chassis-control on
|
||||
SyslogIdentifier=chassis-control
|
||||
+15
@@ -0,0 +1,15 @@
|
||||
[Unit]
|
||||
Description=NCPLite Force Reset Host%i
|
||||
Wants=phosphor-reboot-host@%i.service
|
||||
Conflicts=obmc-chassis-poweroff@%i.target
|
||||
OnFailure=obmc-chassis-powerreset@%i.target
|
||||
|
||||
[Service]
|
||||
RemainAfterExit=no
|
||||
Type=oneshot
|
||||
ExecStart=@SBINDIR@/host-control reset
|
||||
ExecStartPost=/bin/sh -c "busctl call xyz.openbmc_project.Logging.IPMI /xyz/openbmc_project/Logging/IPMI xyz.openbmc_project.Logging.IPMI IpmiSelAdd ssaybq 'Reset Button Pressed' '/xyz/openbmc_project/state/chassis0' 3 0x02 0xff 0xff true 0x0020"
|
||||
SyslogIdentifier=host-control
|
||||
|
||||
[Install]
|
||||
WantedBy=obmc-host-force-warm-reboot@%i.target
|
||||
+16
@@ -0,0 +1,16 @@
|
||||
[Unit]
|
||||
Description=NCPLite Host%i Off
|
||||
Before=obmc-chassis-hard-poweroff@%i.target
|
||||
Before=obmc-chassis-poweroff@%i.target
|
||||
Conflicts=obmc-host-startmin@%i.target
|
||||
OnFailure=obmc-chassis-poweroff@%i.target
|
||||
OnFailureJobMode=flush
|
||||
|
||||
[Service]
|
||||
Type=oneshot
|
||||
ExecStart=@SBINDIR@/host-control gracefuloff
|
||||
ExecStartPost=/bin/sh -c "busctl call xyz.openbmc_project.Logging.IPMI \
|
||||
/xyz/openbmc_project/Logging/IPMI \
|
||||
xyz.openbmc_project.Logging.IPMI IpmiSelAdd ssaybq \
|
||||
'Power Button Pressed' '/xyz/openbmc_project/state/chassis0' \
|
||||
3 0x00 0xff 0xff true 0x0020"
|
||||
@@ -0,0 +1,81 @@
|
||||
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"
|
||||
|
||||
DEPENDS += "gpioplus"
|
||||
DEPENDS += "systemd"
|
||||
|
||||
EXTRA_OEMESON:append = " -Dhost-gpios=enabled"
|
||||
|
||||
SRC_URI += " \
|
||||
file://host-control \
|
||||
file://chassis-control \
|
||||
file://ncplite-chassis-poweroff@.service \
|
||||
file://ncplite-chassis-poweron@.service \
|
||||
file://ncplite-host-off@.service \
|
||||
file://ncplite-host-force-reset@.service \
|
||||
"
|
||||
|
||||
RDEPENDS:${PN}:append = " bash"
|
||||
|
||||
DBUS_PACKAGES:append = "${PN}-ncplite"
|
||||
PACKAGE_BEFORE_PN += "${PN}-ncplite"
|
||||
SYSTEMD_PACKAGES += "${PN}-ncplite"
|
||||
|
||||
SYSTEMD_SERVICE:${PN}-ncplite += "ncplite-chassis-poweron@.service"
|
||||
SYSTEMD_SERVICE:${PN}-ncplite += "ncplite-chassis-poweroff@.service"
|
||||
SYSTEMD_SERVICE:${PN}-ncplite += "ncplite-host-off@.service"
|
||||
SYSTEMD_SERVICE:${PN}-ncplite += "ncplite-host-force-reset@.service"
|
||||
|
||||
# Chassis power on
|
||||
CHASSIS_POWERON_SVC = "ncplite-chassis-poweron@.service"
|
||||
CHASSIS_POWERON_INSTMPL = "ncplite-chassis-poweron@{0}.service"
|
||||
CHASSIS_POWERON_TGTFMT = "obmc-chassis-poweron@{0}.target"
|
||||
CHASSIS_POWERON_FMT = "../${CHASSIS_POWERON_SVC}:${CHASSIS_POWERON_TGTFMT}.requires/${CHASSIS_POWERON_INSTMPL}"
|
||||
SYSTEMD_LINK:${PN}-ncplite += "${@compose_list_zip(d, 'CHASSIS_POWERON_FMT', 'OBMC_CHASSIS_INSTANCES')}"
|
||||
|
||||
# Chassis power off
|
||||
CHASSIS_POWEROFF_SVC = "ncplite-chassis-poweroff@.service"
|
||||
CHASSIS_POWEROFF_INSTMPL = "ncplite-chassis-poweroff@{0}.service"
|
||||
CHASSIS_POWEROFF_TGTFMT = "obmc-chassis-poweroff@{0}.target"
|
||||
CHASSIS_POWEROFF_FMT = "../${CHASSIS_POWEROFF_SVC}:${CHASSIS_POWEROFF_TGTFMT}.requires/${CHASSIS_POWEROFF_INSTMPL}"
|
||||
SYSTEMD_LINK:${PN}-ncplite += "${@compose_list_zip(d, 'CHASSIS_POWEROFF_FMT', 'OBMC_CHASSIS_INSTANCES')}"
|
||||
|
||||
# Host off
|
||||
HOST_OFF_SVC = "ncplite-host-off@.service"
|
||||
HOST_OFF_INSTMPL = "ncplite-host-off@{0}.service"
|
||||
HOST_OFF_TGTFMT = "obmc-host-shutdown@{0}.target"
|
||||
HOST_OFF_FMT = "../${HOST_OFF_SVC}:${HOST_OFF_TGTFMT}.requires/${HOST_OFF_INSTMPL}"
|
||||
SYSTEMD_LINK:${PN}-ncplite += "${@compose_list_zip(d, 'HOST_OFF_FMT', 'OBMC_HOST_INSTANCES')}"
|
||||
|
||||
# Host force reboot
|
||||
HOST_FORCE_RESET_SVC = "ncplite-host-force-reset@.service"
|
||||
HOST_FORCE_RESET_INSTMPL = "ncplite-host-force-reset@{0}.service"
|
||||
HOST_FORCE_RESET_TGTFMT = "obmc-host-force-warm-reboot@{0}.target"
|
||||
HOST_FORCE_RESET_TARGET_FMT = "../${HOST_FORCE_RESET_SVC}:${HOST_FORCE_RESET_TGTFMT}.requires/${HOST_FORCE_RESET_INSTMPL}"
|
||||
SYSTEMD_LINK:${PN}-ncplite += "${@compose_list_zip(d, 'HOST_FORCE_RESET_TARGET_FMT', 'OBMC_HOST_INSTANCES')}"
|
||||
|
||||
# Chassis hard power off require host off in our machine
|
||||
CHASSIS_HARD_POWEROFF_TGTFMT = "obmc-chassis-hard-poweroff@{0}.target"
|
||||
CHASSIS_HOST_OFF_FMT = "../${HOST_OFF_SVC}:${CHASSIS_HARD_POWEROFF_TGTFMT}.requires/${HOST_OFF_INSTMPL}"
|
||||
SYSTEMD_LINK:${PN}-ncplite += "${@compose_list_zip(d, 'CHASSIS_HOST_OFF_FMT', 'OBMC_CHASSIS_INSTANCES')}"
|
||||
|
||||
do_install:append() {
|
||||
install -d ${D}${sbindir}
|
||||
install -m 0744 ${WORKDIR}/host-control ${D}${sbindir}/
|
||||
install -m 0744 ${WORKDIR}/chassis-control ${D}${sbindir}/
|
||||
}
|
||||
|
||||
FILES:${PN} += "${systemd_system_unitdir}/*"
|
||||
FILES:${PN}-host += "${bindir}/phosphor-host-condition-gpio"
|
||||
SYSTEMD_SERVICE:${PN}-host += "phosphor-host-condition-gpio@.service"
|
||||
|
||||
pkg_postinst:${PN}-obmc-targets:prepend() {
|
||||
mkdir -p $D$systemd_system_unitdir/multi-user.target.requires
|
||||
LINK="$D$systemd_system_unitdir/multi-user.target.requires/phosphor-host-condition-gpio@0.service"
|
||||
TARGET="../phosphor-host-condition-gpio@.service"
|
||||
ln -s $TARGET $LINK
|
||||
}
|
||||
|
||||
pkg_prerm:${PN}-obmc-targets:prepend() {
|
||||
LINK="$D$systemd_system_unitdir/multi-user.target.requires/phosphor-host-condition-gpio@0.service"
|
||||
rm $LINK
|
||||
}
|
||||
+7
@@ -0,0 +1,7 @@
|
||||
[Unit]
|
||||
Description=Watchdog Power Cycle
|
||||
|
||||
[Service]
|
||||
Type=oneshot
|
||||
ExecStart=/bin/sh -c "busctl set-property xyz.openbmc_project.State.Host /xyz/openbmc_project/state/host0 xyz.openbmc_project.State.Host RequestedHostTransition s 'xyz.openbmc_project.State.Host.Transition.Reboot'"
|
||||
SyslogIdentifier=phosphor-watchdog"
|
||||
+7
@@ -0,0 +1,7 @@
|
||||
[Unit]
|
||||
Description=Watchdog Power Off
|
||||
|
||||
[Service]
|
||||
Type=oneshot
|
||||
ExecStart=/bin/sh -c "busctl set-property xyz.openbmc_project.State.Chassis /xyz/openbmc_project/state/chassis0 xyz.openbmc_project.State.Chassis RequestedPowerTransition s xyz.openbmc_project.State.Chassis.Transition.Off"
|
||||
SyslogIdentifier=phosphor-watchdog
|
||||
+7
@@ -0,0 +1,7 @@
|
||||
[Unit]
|
||||
Description=Watchdog Reset Host
|
||||
|
||||
[Service]
|
||||
Type=oneshot
|
||||
ExecStart=/bin/sh -c "busctl set-property xyz.openbmc_project.State.Host /xyz/openbmc_project/state/host0 xyz.openbmc_project.State.Host RequestedHostTransition s xyz.openbmc_project.State.Host.Transition.ForceWarmReboot"
|
||||
SyslogIdentifier=phosphor-watchdog
|
||||
+16
@@ -0,0 +1,16 @@
|
||||
[Unit]
|
||||
Description=Phosphor Watchdog
|
||||
|
||||
[Service]
|
||||
ExecStart=/usr/bin/phosphor-watchdog --continue --service=xyz.openbmc_project.Watchdog \
|
||||
--path=/xyz/openbmc_project/watchdog/host0 \
|
||||
--action_target=xyz.openbmc_project.State.Watchdog.Action.HardReset=phosphor-watchdog-host-reset.service \
|
||||
--action_target=xyz.openbmc_project.State.Watchdog.Action.PowerOff=phosphor-watchdog-host-poweroff.service \
|
||||
--action_target=xyz.openbmc_project.State.Watchdog.Action.PowerCycle=phosphor-watchdog-host-cycle.service \
|
||||
|
||||
SyslogIdentifier=phosphor-watchdog
|
||||
BusName=xyz.openbmc_project.Watchdog
|
||||
Type=dbus
|
||||
|
||||
[Install]
|
||||
WantedBy=basic.target
|
||||
@@ -0,0 +1,9 @@
|
||||
FILESEXTRAPATHS:prepend:ncplite := "${THISDIR}/${PN}:"
|
||||
|
||||
# Remove the override to keep service running after DC cycle
|
||||
SYSTEMD_OVERRIDE:${PN}:remove:ncplite = "poweron.conf:phosphor-watchdog@poweron.service.d/poweron.conf"
|
||||
SYSTEMD_SERVICE:${PN}:ncplite = " phosphor-watchdog.service \
|
||||
phosphor-watchdog-host-poweroff.service \
|
||||
phosphor-watchdog-host-cycle.service\
|
||||
phosphor-watchdog-host-reset.service\
|
||||
"
|
||||
Reference in New Issue
Block a user